Escher Wyss

Backpressure Turbo-Alternator Set
Images/TechnicalServices/Trading/EW/EW picture01-thumb.jpg

Specifications:

 
Year of Construction : 
1972
Output (AC) : 8,940 kW
Type : NGH 125
Speed :  9,300 rpm
Live Steam Pressure : 57 bar - max. 60 bar
Live Steam Temperature :  525 °C - max. 530 °C
Steamflow: max. 60t/h
Pass-out after stage 1 (uncontrolled): 30.5 bar / 455 °C - 4 t/h
Pass-out after stage 1 (uncontrolled): 21.6 bar / 412 °C - 4 t/h
Backpressure : 4.2 bar / 226 °C

 
Figures:

Performance Figures
When operated at 57 bar / 525 °C live steam and 4.2 bar backpressure without pass-out

 
Output  8,940 6,745 4,910  kW
Live steamflow 114.0 90.5 64.4 t/h
Spec. steamconsumption 7.60 6.03 5.90 kg/kWh

 

Scheme:

Click on the thumbnail to view the full scheme.

Images/TechnicalServices/Trading/EW/EWscheme01-thumb.jpg

Images/TechnicalServices/Trading/EW/EW scheme02-thumb.jpg

 

Top view of the general arrangement drawings  Sectional/Longitudial view of the general arrangement drawings    

 

Pictures:

Click on the thumbnail to view a larger picture.

Images/TechnicalServices/Trading/EW/EW picture01-thumb.jpg

Turbine as it was installed.